Welcome to our store Learn more

New collections added! Learn more

Victron Energy  |  SKU: TMS-88341

Victron Argofet 200-2 Battery Isolator - 200AMP - 2 Batteries [ARG200201020]

$207.00 $244.00
Shipping calculated at checkout.


Care information

Please follow the manufacturer’s care recommendations as provided in the product manual.

Delivery and Shipping

All orders placed by 4pm EST will ship the same day as long as everything requested is currently in stock.

Shipping would be either via UPS, Canada Post or USPS.

All orders outside the United States may incur Custom charges of your country.

" Gear up, Dive In, Discover More. "

Argofet 200-2 Battery Isolator - 200AMP - 2 Batteries

Similarly, to Argodiode battery isolators, Argofet isolators allow simultaneous charging of two or more batteries from one alternator (or a single output battery charger) without connecting the batteries. Discharging the accessory battery, for example, will not result in discharging the starter battery.  

In contrast with Diode battery isolators, FET isolators have virtually no voltage loss. The voltage drop is less than 0,02 Volt at low currents and averages 0,1 Volt at higher currents.

When using Argofet battery isolators, there is no need to also increase the output voltage of the alternator. However, care should be taken to keep cable lengths short and of sufficient cross-section.

Example: When a current of 100 A flows through a cable of 50 mm² cross section (AWG 0) and 10 m length (30 ft), the voltage drop over the cable will be 0,26 Volt. Similarly, a current of 50 A through a cable of 10 mm² cross section (AWG 7) and 5 m length (15 ft) will result in a voltage drop of 0,35 volts!

Alternator Energizes Input

Some alternators need DC voltage on the B+ output to start charging. DC will be present when the alternator is directly connected to a battery. Inserting an Argodiode or Argofet splitter will however prevent any return voltage/current from the batteries to the B+, and the alternator will not start.

The new Argofet Isolators have a special current-limited energize input that will power the B+ when the engine run/stop switch is closed. 

Specifications:

  • Maximum Charge Current (A): 200
  • Maximum Alternator Current (A): 200
  • Number of Batteries: 2
  • Nominal Battery Voltage: 12V and 24V
  • Connection: M8 bolts
  • Weight kg (lbs): 1,4 (3.1)
  • Dimensions (H x W x D): 65 x 120 x 200 mm (2.6 x 4.7 x 7.9 inches)
Please contact your dealer for any returns, repairs or support issues related to this product.
Quick Guide (pdf)
Owner's Manual (pdf)
Brochure (pdf)

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Help and Advice

Need a few things clearing up? Check out our Help and Advice section.

Victron Energy

Victron Argofet 200-2 Battery Isolator - 200AMP - 2 Batteries [ARG200201020]

$207.00 $244.00

Argofet 200-2 Battery Isolator - 200AMP - 2 Batteries

Similarly, to Argodiode battery isolators, Argofet isolators allow simultaneous charging of two or more batteries from one alternator (or a single output battery charger) without connecting the batteries. Discharging the accessory battery, for example, will not result in discharging the starter battery.  

In contrast with Diode battery isolators, FET isolators have virtually no voltage loss. The voltage drop is less than 0,02 Volt at low currents and averages 0,1 Volt at higher currents.

When using Argofet battery isolators, there is no need to also increase the output voltage of the alternator. However, care should be taken to keep cable lengths short and of sufficient cross-section.

Example: When a current of 100 A flows through a cable of 50 mm² cross section (AWG 0) and 10 m length (30 ft), the voltage drop over the cable will be 0,26 Volt. Similarly, a current of 50 A through a cable of 10 mm² cross section (AWG 7) and 5 m length (15 ft) will result in a voltage drop of 0,35 volts!

Alternator Energizes Input

Some alternators need DC voltage on the B+ output to start charging. DC will be present when the alternator is directly connected to a battery. Inserting an Argodiode or Argofet splitter will however prevent any return voltage/current from the batteries to the B+, and the alternator will not start.

The new Argofet Isolators have a special current-limited energize input that will power the B+ when the engine run/stop switch is closed. 

Specifications:

Please contact your dealer for any returns, repairs or support issues related to this product.
Quick Guide (pdf)
Owner's Manual (pdf)
Brochure (pdf)
View product